תיקון שבר בתותבת אקריל : הקשיה במיקרוגל או הקשיה כימית רגילה ?

תיקון שבר בתותבת  אקריל – אין יתרון לאקריל מוקשה במיקרוגל על פני אקריל בהקשיה כימית רגילה:

למאמר

לפניכם התקציר:

Repair strength of autopolymerizing, microwave, and conventional heat polymerized acrylic resins, Rodrigo Nunes Rached DDS, MS, PhD, John M. Powers PhD and Altair Antoninha Del Bel Cury DDS, MS, PhD
Statement of problem

Acrylic resin dentures are susceptible to fracture after clinical use. The repair procedure should be time saving, strong, and should not affect dimensional accuracy.
Purpose

This study evaluated the transverse repair strength of a conventional heat-polymerized (Lucitone 199, “L”) and a microwave-polymerized (Acron MC, “A”) acrylic resin that were repaired with these same resins and with an autopolymerizing acrylic resin (Acron MC/R, “AR”).
Material and methods

Twenty-four rectangular specimens (65.0 × 10.0 × 3.3 mm) of L or A and 6 of AR were manufactured according to ISO/FDI 1567 and stored in distilled water at 37°C for 7 days. Eighteen specimens of L or A were selected randomly. Six specimens of each material remained intact (control), each 6 were sectioned in the middle to create a 10-mm gap and repaired with the materials L, A, or AR. After an additional 7 days of storage at 37°C, the transverse strength (MPa) of the repaired and intact specimens was measured using a 3-point bending test. A 2-way ANOVA and a Tukey HSD test were performed to identify significant differences (small alpha, Greek=.05). The nature of the failure was noted as adhesive, cohesive, or mixed.

Results

The intact and repaired specimens showed similar transverse strength values (MPa), except for A-intact (80.6 ± 2.9), which was significantly stronger (P<.05) than the other materials tested as well as the repaired groups (P<.05). No differences were detected among the repaired groups. Repaired specimens exhibited 3 types of failures: adhesive (interface), cohesive (only in the repair material), and mixed (interface and repair material), with incidences of 2.8, 25, and 72.2%, respectively.
Conclusion

The autopolymerizing resin exhibited a repair strength similar to those found for the conventional heat- and microwave-polymerized materials.

תגובות רוצה להצטרף לדיון?

אין תגובות עדיין. היה הראשון להגיב!

מאמרים

שיקום: גשרים מחרסינה

מערכת האתר
מערכת האתר
אין תגובות|19/03/2005

גשרים מחרסינה בלבד בהחלט יכולים לשמש כקנטיליבר .  נבדקו גשרים

כניסת צוות רפואי

הכניסה לאתר מותרת אך ורק לצוות הרפואי

לקבלת קוד אימות לנייד ולמייל, יש למלא את כתובת המייל ואת מספר הטלפון שלך

עדיין לא נרשמת? באפשרותך לבצע רישום כאן